GL-9084 – Network Adapter

Main features

– Various type of protocols (MODBUS TCP , EtherNet IP , PROFINET , EtherCAT , CC-Link IE , CC-Link IE Field Basic , DeviceNet , PROFIBUS , MODBUS RS485, CC-Link , CanOpen , BACnet ,MODBUS RTU)

– More than 90 different I/Os (Universal type of Digital Input module, 32 points slice I/O module, ERNI type connector input/output module)

– Space-saving, compact size & slice type for the module expansion

– Easy and convenient working environment for the operator when wiring and install

Catalog

 

User Manual

 

 

 

Description

Interface Specification, GL-9284 (MODBUS TCP/UDP NETWORK ADAPTER)
Adapter TypeSlave station (CC-Link IE Field Basic Server)
ProtocolCC-Link IE Field Basic, SLMP
Sub-ProtocolMODBUS/TCP,MODBUS/UDP,HTTP,DHCP,10 TCP Connections
Port number61450 (CyclicData)

61451 (port number of the slave station of NodeSerch)

Max. Expantsion Module16 slots
Number of occupied stations1 ~ 4 stations
Max. Data Size(RX, RY)each 32 bytes (4 Stations occupied)
Max. Data Size(RWr, RWw)each 256 bytes (4 Stations occupied)
Max. Input / Output Data SizeMax. Input 256 bytes / Output 256 bytes
Max. link points per station (RX, RY)each 64 points
Max. link points per station
(RWr, RWw)
each 32 points
Max Length Bus LineUp to 100m from Ethernet Hub/Switch with twisted CAT5 UTP/STP
Max. Nodes64 node
Baud Rate10/100Mbps, Auto-negotiation, Full duplex
Interface ConnectorRJ-45 socket * 2pcs
IP-Address SetupVia DHCP/BOOTP or IOGuide(Crevis Software)
IP-Address Rangexxx.xxx.xxx.1 ~ 253 (User area)

xxx.xxx.xxx.254 ~ 255 (Reserved for IAP Function)

IAP ModeWhen DIP Switch 1 to 8 setting is 254 or 255

(Using only Internet Explorer / recommended version 11)

Indicator4 LEDs

1 Green/Red, Module Status (MOD)

1 Green, Physical Connection (NET)

1 Green, Exchange Data/Traffic Present (ERR)

1 Green/Red, Expansion I/O Module Statsus (IOS)

2 LEDs (each RJ45 Connector)

1 Yellow, Link/Active

1 Green, Not used

Module LocationStarter module left side of G-Series system
General Specification
UL System PowerSupply voltage : 24Vdc nominal, Class2
System PowerSupply voltage : 24Vdc nominal

Supply voltage range : 15~28.8Vdc

Reverse polarity protection

Power Dissipation60mA typical @ 24Vdc
Current for I/O Module1.0A @ 5Vdc
IsolationSystem power to internal logic : Non-isolation
System power I/O driver : Isolation
UL Field PowerSupply voltage : 24Vdc nominal, Class2
Field PowerSupply voltage : 24Vdc typical (Max. 30Vdc)

* Field Power Range is different depending on IO Module series.

Refer to IO Module`s Specification.

Max. Current Field Power ContactDC 8A Max
WiringI/O Cable Max. 2.0㎟(AWG 14)
Torque0.8Nm(7 lb-in)
Weight76g
Module Size22mm x 109mm x 70mm
Environment ConditionRefer to ‘1. Environment Specification’
Pin NoSignal Description
1System Power, 24V
2System Power, Ground
3F.G
4Field Power, Ground
5Field Power, 24V